Intelligent Building Control Center for KNX, BACnet, M-Bus, LoRaWAN and Edge Automation


The Robustel LG5120 is an industrial-grade edge computing gateway engineered specifically for building automation and facility management. Where most IoT gateways aggregate data and forward it upstream, the LG5120 is designed to act on it locally — running automation logic, triggering controls, and generating dashboards at the edge while syncing with cloud platforms for centralised reporting and fleet management.

The hardware is built around the protocols buildings actually use. A dedicated KNX TP port and KNXnetIP over Ethernet connect directly to lighting systems, HVAC controllers, and room management units without a protocol converter. Two isolated RS-485 ports handle Modbus RTU and BACnet MS/TP field devices. M-Bus manages heat, water, and energy meter networks. A dedicated P1/DSMR port (up to 115,200 bps) connects directly to high-speed Dutch smart meters for real-time consumption data — particularly relevant for EU868 deployments in the Netherlands and Belgium. Two software-configurable analog inputs (0–24V or 4–20mA) accommodate sensors that don’t use a digital bus. An onboard Semtech SX1302 LoRaWAN chipset covers wireless sensors — temperature, humidity, occupancy, CO₂ — across 8 simultaneous channels on EU868, AU915, or AS923 frequency plans.

Processing runs on a Quad-core ARM Cortex-A53 at 1.6 GHz with an integrated NPU rated at 2.3 TOPS, 8 GB DDR4, and 64 GB eMMC — with 7 GB of RAM and 60 GB of flash available to the SDK. The E2C Facility Suite provides the software framework: unified data acquisition across KNX, BACnet, Modbus, and OPC-UA; Node-RED orchestration with automated scene management for trigger-based control; BACnet IP and OPC-UA data forwarding to external BMS or SCADA systems; and a drag-and-drop HMI/SCADA dashboard builder with real-time multi-channel alarms.

INTEGRACIÓN DE LNS

Compatible con UDP, LoRa Basics™ Station, LORIOT y un Chirpstack LNS interno.

LoRaWAN BACKHAUL

Añada redundancia Dual-SIM celular y Wi-Fi back-haul a su red LoRaWAN.

BUILDING PROTOCOL

KNX TP + KNXnetIP, BACnet MS/TP, Modbus RTU, M-Bus, and OPC-UA onboard.

SISTEMA OPERATIVO

RobustOS Pro: sistema operativo Linux Debian completo para alojar aplicaciones IoT.

RCMS A BORDO

Gestión de dispositivos RCMS Cloud habilitada para una mayor escalabilidad.

Example LG5120 Use Cases

Commercial Buildings & Offices

Modern commercial buildings run HVAC, lighting, access control, and sub-metering on separate subsystems that rarely share data. The LG5120 consolidates them — KNX TP handles lighting and room controllers, Modbus or BACnet MS/TP connects HVAC and VFDs, LoRaWAN picks up occupancy and IAQ sensors, and the E2C Facility Suite aggregates the combined data stream locally. Automated scene logic adjusts climate and lighting based on occupancy patterns without waiting for cloud instructions, while the built-in dashboard makes consumption and comfort metrics visible to facilities teams in real time.

Energy Management & Carbon

The M-Bus port aggregates heat, water, and gas meter readings from distributed sub-metering networks. The P1/DSMR port pulls high-resolution electricity consumption data directly from smart meters in the Netherlands, Belgium, and other compatible markets. Combined with LoRaWAN-connected energy monitoring sensors and the E2C Facility Suite’s local processing, the LG5120 can generate granular consumption records and forward structured energy data to RCMS or third-party carbon reporting platforms — supporting energy audit requirements and carbon-neutrality targets without manual data collection.

Healthcare, Campus & Facilities

Hospitals and schools share a demanding operational profile: continuous environmental monitoring, strict energy compliance requirements, and facilities staff who need clear visibility without deep technical expertise. The LG5120’s local processing ensures that alarm conditions — temperature deviation in a pharmacy cold store, CO₂ levels in a classroom — trigger responses at the edge with minimal latency. BACnet IP and OPC-UA data forwarding integrates with existing BMS and SCADA platforms already deployed in larger facilities, without requiring a full system replacement.

¿Buscas más casos de uso?


Con millones de dispositivos Robustel instalados en más de 100 países, es imposible abarcar todos los casos de uso mencionados anteriormente. Explore los enlaces que aparecen a continuación para descubrir algunas de las formas emocionantes e innovadoras en las que nuestra tecnología está teniendo un impacto en todo el mundo.

Este dispositivo está preparado para RCMS.


RCMS es una plataforma de gestión de dispositivos IoT basada en la nube que le ofrece visibilidad en tiempo real de toda su flota Robustel. De este modo, puede solucionar problemas, actualizar y optimizar el rendimiento desde cualquier lugar y en cualquier momento, sin necesidad de enviar ingenieros al lugar.

Opciones de montaje del producto

Soporte para escritorio

Montaje en carril DIN

Montaje en pared

NOTA: El producto aún se encuentra en fase de desarrollo, por lo que las especificaciones están sujetas a cambios hasta el inicio de la producción.

Arquitectura del sistema

Sistema operativo

RobustOS Pro

CPU

Quad-core Cortex-A53, 1.6 GHz

NPU

2.3 TOPS

RAM

8 GB DDR4

Flash

64 GB eMMC

Celular

Tecnologías compatibles

4G/LTE, 3G, 2G

Antenas

2 (PRINCIPAL + DIV)

Conector

SMA-K

SIM

2 x Mini SIM (2FF)

Ethernet

Puertos Ethernet

2 x RJ45, 10/100/1000 Mbps, compliant with 1000BASE-T; configurable as 1 x WAN + 1 x LAN or 2 x LAN

Protección de aislamiento magnético

1.5 kV

LoRa

Antenas

1

Conector

RP-SMA-K

Frecuencias

US915
EU868
AU915
AS923

Capacidad del canal

Supports up to 8 channels receiving data simultaneously

Puerto serie

Puertos serie

1 x M-Bus, 1 x KNX, 1 x P1, 2 x isolated RS-485, 1 x RS-232

Conector

Bloque de terminales de 3,5 mm

Definición de señal

M-bus: M+, M-
KNX: K+, K-
P1: P1-R, P1-D, GND
RS-232: TXD, RXD, GND
RS-485: Data+(A), Data-(B), GND

Entrada/salida digital

Puertos DI/DO

2 x DI + 2 x DO, wet contact

Conector

Bloque de terminales de 3,5 mm

Aislamiento

Bidirectional optocoupler for DI; unidirectional optocoupler for DO

Absolute Maximum Voltage

+30 VDC

Absolute Maximum Current

100 mA

Definición de señal

DI1+, DI2+, DIcom, DO1+, DO2+, DOcom

Analog Input Port

Number of interfaces

2 x AI

Data reading type

Voltage / Current type, software configurable

Voltage input range

0–24 V

Current input range

4–20 mA

Signal definition

AI1+, GND, AI2+, GND

Wi-Fi Interface

Number of antennas

1 x RP-SMA-K, supporting only 1T1R

Normas

802.11 a/b/g/n/ac/ax, supports AP and client modes

Frequency bands

2.412–2.472 GHz (2.4 GHz ISM band)
5.15–5.825 GHz (5 GHz ISM band)

Otras interfaces

GNSS

Integrated GNSS with Cellular module

SD

1 x microSD

Botón de reinicio

1 x RST

Indicadores LED

1 x RUN, 1 x Signal, 1 x USR, and 1 x MDM

Organismo de control

Externo

USB

1 x USB 3.0 (host), Type A, 5 V, 500 mA

RTC

Remains functional up to 7 days after power loss

Suministro y consumo de energía

Conector PSU

Bloque de terminales de 2 pines de 3,5 mm con bloqueo

Voltaje de entrada

12/24/48 V DC, 9–60 V DC,
reverse polarity protection,
surge protection

Consumo de energía

En reposo: 5 W a 12 V
Máximo: 20 W a 12 V

Fuente de alimentación recomendada

Adaptador de corriente de 12 V CC/1,5 A

Características físicas

Protección contra la entrada de agua y polvo

IP30

Carcasa y peso

Metal, 560 g

Dimensiones

49 x 105 x 128 mm

Opciones de instalación

De sobremesa, montaje en pared y carril DIN de 35 mm

Temperatura de funcionamiento

-40 – +70 °C

Temperatura de almacenamiento

-40 – +85 °C

Humedad relativa

5 – 95 % HR (sin condensación)

Características del software

Protocolos LoRaWAN

V1.0.4 Clase A/Clase B/Clase C

Protocolos de red

PPP, PPPoE, ARP, VLAN, ICMP, NAT, TCP, UDP, DHCP, DNS, DDNS, NTP, HTTP, HTTPS, Telnet, SSH2, SMTP, Static Routing, etc.

Túneles VPN

IPsec, OpenVPN, GRE, L2TP, PPTP, DMVPN, WireGuard

Cortafuegos

DMZ, anti-DDoS, filtrado (IP/nombre de dominio/dirección MAC), mapeo de puertos, control de acceso.

Gestión remota

RCMS, Web, CLI, SMS

Protocolos de puerto serie

Transparente, cliente/servidor TCP, UDP, pasarela Modbus RTU

Gestión de SIM

Smart Roaming V3, Language, etc.

Aplicaciones opcionales

Request on demand

E2C Facility Suite

LNS configuration

Built-in LoRaWAN Network Server with zero-code sensor integration

Data collection

Unified polling for KNX, BACnet, Modbus, and OPC-UA protocols

Logic Orchestration & Scenario Management

Node-RED orchestration and automated scene management for trigger-based control

Data forwarding

Converts edge data into BACnet/IP and OPC UA data streams for external systems

Alarms and Visualization

Real-time multi-channel alerts and a drag-and-drop HMI/SCADA dashboard builder

Kit de desarrollo de software (SDK)

Lenguajes de programación compatibles

C, C++, Python, Java, Node.js, etc. (para que los usuarios desarrollen sus propias aplicaciones)

Flash disponible para SDK

60 GB

RAM disponible para SDK

7 GB

Aprobaciones reglamentarias y de tipo

Medioambiental

RoHS 2.0

EMI

EN 55032 Emisiones conducidas Clase B
EN 55032 Emisiones radiadas Clase B

EMS

EN 61000-4-2 (ESD) Contact Level 3
EN 61000-4-3 (RS) Level 3
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge)  Level 3, AC Mains Power Port; Level 3, Signal Ports
EN 61000-4-6 (CS) Level 3
EN 61000-4-11 (Dips)

Modelos disponibles

Modelo

Bandas de frecuencia compatibles

Frecuencia LoRa compatible

Certificaciones

Código de pedido

Contenido del paquete

LG5120-GBKGC-4L-A35GL
EU

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28
LTE TDD: B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

EU868

A016000001

1 x LG5120
(B Code: B016000001)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GCKGC-4L-A35GL
ANZ

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28
LTE TDD: B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AU915

A016000002

1 x LG5120
(B Code: B016000002)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GEKGC-4L-A35GL
Asia

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28
LTE TDD: B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AS923

A016000003

1 x LG5120
(B Code: B016000003)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

NOTA:
1. Para obtener más información sobre las variantes específicas de cada región y operador, póngase en contacto con nosotros en
2. * Indica que la certificación está en curso.

LG5120 Downloads

Tenga en cuenta que todas las descargas de productos se encuentran ahora en la base de conocimientos de Robustel (https://support.robustel.com). Los botones siguientes le llevarán a las secciones correspondientes a cada producto.

Documentación del producto


Firmware, software y aplicaciones

Más información sobre Robustel