Robustel LG5120

Intelligent Building Edge Controller for KNX, BACnet, M-Bus, LoRaWAN and Edge Automation


The Robustel LG5120 is an industrial-grade edge computing gateway engineered specifically for building automation and facility management. Where most IoT gateways aggregate data and forward it upstream, the LG5120 is designed to act on it locally — running automation logic, triggering controls, and generating dashboards at the edge while syncing with cloud platforms for centralised reporting and fleet management.

The hardware is built around the protocols buildings actually use. A dedicated KNX TP port and KNXnetIP over Ethernet connect directly to lighting systems, HVAC controllers, and room management units without a protocol converter. Two isolated RS-485 ports handle Modbus RTU and BACnet MS/TP field devices. M-Bus manages heat, water, and energy meter networks. A dedicated P1/DSMR port (up to 115,200 bps) connects directly to high-speed Dutch smart meters for real-time consumption data — particularly relevant for EU868 deployments in the Netherlands and Belgium. Two software-configurable analog inputs (0–24V or 4–20mA) accommodate sensors that don’t use a digital bus. An onboard Semtech SX1302 LoRaWAN chipset covers wireless sensors — temperature, humidity, occupancy, CO₂ — across 8 simultaneous channels on EU868, AU915, AS923, and US915 frequency plans.

Processing runs on a Quad-core ARM Cortex-A53 at 1.6 GHz with an integrated NPU rated at 2.3 TOPS, 8 GB DDR4, and 64 GB eMMC — with 6 GB of RAM and 50 GB of flash available to the SDK. The E2C Facility Suite provides the software framework: unified data acquisition across KNX, BACnet, Modbus, and OPC-UA; Node-RED orchestration with automated scene management for trigger-based control; BACnet IP and OPC-UA data forwarding to external BMS or SCADA systems; and a drag-and-drop HMI/SCADA dashboard builder with real-time multi-channel alarms.

LNS統合

UDP、LoRa Basics™ Station、LORIOT、および内蔵Chirpstack LNSのサポート。

LoRaWAN バックホール

LoRaWANネットワークにデュアルSIMによる冗長化されたセルラー通信とWi-Fiバックホールを追加します。

BUILDING PROTOCOL

KNX TP + KNXnetIP, BACnet MS/TP, Modbus RTU, M-Bus, and OPC-UA onboard.

オペレーティングシステム

RobustOS Pro – IoTアプリケーションのホスティング向け完全版Linux Debianオペレーティングシステム。

RCMS 搭載

RCMS Cloudデバイス管理を有効化し、拡張性を強化しました。

Example LG5120 Use Cases

Commercial Buildings & Offices

Modern commercial buildings run HVAC, lighting, access control, and sub-metering on separate subsystems that rarely share data. The LG5120 consolidates them — KNX TP handles lighting and room controllers, Modbus or BACnet MS/TP connects HVAC and VFDs, LoRaWAN picks up occupancy and IAQ sensors, and the E2C Facility Suite aggregates the combined data stream locally. Automated scene logic adjusts climate and lighting based on occupancy patterns without waiting for cloud instructions, while the built-in dashboard makes consumption and comfort metrics visible to facilities teams in real time.

Energy Management & Carbon

The M-Bus port aggregates heat, water, and gas meter readings from distributed sub-metering networks. The P1/DSMR port pulls high-resolution electricity consumption data directly from smart meters in the Netherlands, Belgium, and other compatible markets. Combined with LoRaWAN-connected energy monitoring sensors and the E2C Facility Suite’s local processing, the LG5120 can generate granular consumption records and forward structured energy data to RCMS or third-party carbon reporting platforms — supporting energy audit requirements and carbon-neutrality targets without manual data collection.

Healthcare, Campus & Facilities

Hospitals and schools share a demanding operational profile: continuous environmental monitoring, strict energy compliance requirements, and facilities staff who need clear visibility without deep technical expertise. The LG5120’s local processing ensures that alarm conditions — temperature deviation in a pharmacy cold store, CO₂ levels in a classroom — trigger responses at the edge with minimal latency. BACnet IP and OPC-UA data forwarding integrates with existing BMS and SCADA platforms already deployed in larger facilities, without requiring a full system replacement.

さらに多くのユースケースをお探しですか?


100カ国以上に展開された数百万ロバステル 、上記のすべてのユースケースを網羅することは不可能です。下記リンクから、当社の技術が世界中で革新的な方法で影響を与えている事例をご覧ください。

このデバイスはRCMS対応です


RCMSはクラウドベースのIoTデバイス管理プラットフォームであり、ロバステル リアルタイムで可視化します。これにより、エンジニアを現場に派遣することなく、いつでもどこからでもトラブルシューティング、更新、パフォーマンス最適化が可能になります。

製品取り付けオプション

デスクトップマウント

DINレール取付

壁掛け

システムアーキテクチャ

オペレーティングシステム

ロバストOS プロ

CPU

Quad-core Cortex-A53, 1.6 GHz

NPU

2.3 TOPS

RAM

8 GB DDR4

フラッシュ

64 GB eMMC

セルラー

サポート対象技術

4G/LTE、3G、2G

アンテナ

2 (メイン + ディビジョン)

コネクタ

SMA-K

SIM

2 x ミニSIM (2FF)

イーサネット

イーサネットポート

2 x RJ45, 10/100/1000 Mbps, compliant with 1000BASE-T; configurable as 1 x WAN + 1 x LAN or 2 x LAN

磁気絶縁保護

1.5 kV

LoRa

アンテナ

1

コネクタ

RP-SMA-K

周波数

EU868
AU915
AS923
US915

Sensitivity

-140 dBm Sensitivity @ 292 bps

Tx power

27 dBm Max (Conducted, adjustable per regional regulations)

プロトコル

LoRaWAN V1.0.4, supporting Class A and Class C

チャネル容量

Up to 8 channels for simultaneous data reception

Device capacity

Up to 2,000 LoRaWAN end devices

シリアルポート

シリアルポート

1 x M-Bus, 1 x KNX, 1 x P1, 2 x isolated RS-485, 1 x RS-232

コネクタ

3.5 mm 端子台

信号定義

M-bus: M+, M-
KNX: K+, K-
P1: P1-R, P1-D, GND
RS-232: TXD, RXD, GND
RS-485: Data+(A), Data-(B), GND

デジタル入出力

DI/DOポート

2 x DI + 2 x DO, wet contact

コネクタ

3.5 mm 端子台

隔離

Bidirectional optocoupler for DI; unidirectional optocoupler for DO

Absolute Maximum Voltage

+30 VDC

Absolute Maximum Current

100 ミリアンペア

信号定義

DI1+, DI2+, DIcom, DO1+, DO2+, DOcom

Analog Input Port

Number of interfaces

2 x AI

Data reading type

Voltage / Current type, software configurable

Voltage input range

0–24 V

Current input range

4–20 mA

Signal definition

AI1+, GND, AI2+, GND

Wi-Fi Interface

Number of antennas

1 x RP-SMA-K, supporting only 1T1R

基準

802.11 a/b/g/n/ac/ax, supports AP and client modes

Frequency bands

2.412–2.472 GHz (2.4 GHz ISM band)
5.15–5.825 GHz (5 GHz ISM band)

その他のインターフェース

GNSS

GNSS integrated into the cellular module

SD

1 x microSD

Reset button

1個 RST

USB port

1 x USB 3.0 (host), Type-A, 5 V, 900 mA

LED indicators

1 x RUN, 1 x Signal, 1 x USR, and 1 x MDM

監視機関

外部

RTC

Remains functional up to 7 days after power loss

電源供給と消費電力

PSUコネクタ

ロック付き2ピン3.5mm端子台

入力電圧

12/24/48 V DC, 9–60 V DC,
reverse polarity protection, surge protection

消費電力

Idle: 5 W@12 V
Max: 16 W@12 V

推奨電源

12 V DC/1.5 A 電源アダプター

物理的特性

侵入保護等級

IP30

ハウジングと重量

Metal, 560 g

寸法

49 × 105 × 128 mm

インストールオプション

デスクトップ、壁掛け、35mm DINレール

動作温度

-40 ~ +70°C

保存温度

-40 ~ +85°C

相対湿度

5~95% RH(結露なきこと)

ソフトウェア機能

ネットワークプロトコル

PPP, PPPoE, ARP, VLAN, ICMP, NAT, TCP, UDP, DHCP, DNS, DDNS, NTP, HTTP, HTTPS, Telnet, SSH2, SMTP, Static Routing, etc.

VPNトンネル

IPsec, OpenVPN, GRE, L2TP, PPTP, DMVPN, WireGuard

ファイアウォール

DMZ, anti-DoS, Filtering (IP/Domain name/MAC address), Port Mapping, Access Control

リモート管理

Web, CLI, SMS, RCMS

シリアルポートプロトコル

透過型、TCPクライアント/サーバー、UDP、Modbus RTUゲートウェイ

SIM管理

Smart Roaming V3, Language, etc.

オプションアプリ

Request on demand

E2C Facility Suite

LNS configuration

Built-in LoRaWAN Network Server with zero-code sensor integration

Data collection

Unified polling for KNX, BACnet, Modbus, and OPC UA protocols

Logic Orchestration & Scenario Management

Node-RED orchestration and automated scene management for trigger-based control

Data forwarding

Converts edge data into BACnet/IP and OPC UA data streams for external systems

Alarms & Visualization

Real-time multi-channel alerts and a drag-and-drop HMI/SCADA dashboard builder

Niagara Station

Supports lightweight BMS deployment with advanced edge logic, intelligent alarm management, and graphical visualization

ソフトウェア開発キット (SDK)

サポート対象プログラミング言語

C、C++、Python、Java、Node.js など(ユーザーが独自のアプリケーションを開発するためのもの)

SDK用に利用可能なRAM

6 GB

FlashがSDKで利用可能

50 GB

規制および型式承認

環境

RoHS指令2.0

EMI

EN 55032 伝導エミッション クラスB
EN 55032 放射エミッション クラスB

EMS

EN 61000-4-2 (ESD) Level 3
EN 61000-4-3 (RS) Level 3
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge)  Level 3, AC Mains Power Port; Level 3, Signal Ports
EN 61000-4-6 (CS) Level 3
EN 61000-4-11 (Dips)

利用可能なモデル

モデル

対応周波数帯域

サポートされているLoRa周波数

認証

注文コード

パッケージ内容

LG5120-GBKGC-4L-A35GL
EU

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

EU868

CE、UKCA

A016000001

1 x LG5120
(B Code: B016000001)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x GNSS Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GCKGC-4L-A35GL
AU

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AU915

RCM

A016000002

1 x LG5120
(B Code: B016000002)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x GNSS Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GEKGC-4L-A35GL
Asia

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AS923

–

A016000003

1 x LG5120
(B Code: B016000003)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x GNSS Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GDKGC-4L-A35GL
NA

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

US915

–

A016000004

1 x LG5120
(B Code: B016000004)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x GNSS Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

注記:
1. 地域および通信事業者固有のバリエーションに関する詳細情報は、当社までお問い合わせください
2. * は認証取得中を示します

LG5120 Downloads

すべての製品ダウンロードは、ロバステル (ロバステル)に移動しました。下記のボタンから各製品の関連セクションにアクセスできます。

製品ドキュメント


ファームウェア、ソフトウェア、アプリケーション

ロバステルからさらに探す