Robustel LG5120
Intelligent Building Control Center for KNX, BACnet, M-Bus, LoRaWAN and Edge Automation
The Robustel LG5120 is an industrial-grade edge computing gateway engineered specifically for building automation and facility management. Where most IoT gateways aggregate data and forward it upstream, the LG5120 is designed to act on it locally — running automation logic, triggering controls, and generating dashboards at the edge while syncing with cloud platforms for centralised reporting and fleet management.
The hardware is built around the protocols buildings actually use. A dedicated KNX TP port and KNXnetIP over Ethernet connect directly to lighting systems, HVAC controllers, and room management units without a protocol converter. Two isolated RS-485 ports handle Modbus RTU and BACnet MS/TP field devices. M-Bus manages heat, water, and energy meter networks. A dedicated P1/DSMR port (up to 115,200 bps) connects directly to high-speed Dutch smart meters for real-time consumption data — particularly relevant for EU868 deployments in the Netherlands and Belgium. Two software-configurable analog inputs (0–24V or 4–20mA) accommodate sensors that don’t use a digital bus. An onboard Semtech SX1302 LoRaWAN chipset covers wireless sensors — temperature, humidity, occupancy, CO₂ — across 8 simultaneous channels on EU868, AU915, or AS923 frequency plans.
Processing runs on a Quad-core ARM Cortex-A53 at 1.6 GHz with an integrated NPU rated at 2.3 TOPS, 8 GB DDR4, and 64 GB eMMC — with 7 GB of RAM and 60 GB of flash available to the SDK. The E2C Facility Suite provides the software framework: unified data acquisition across KNX, BACnet, Modbus, and OPC-UA; Node-RED orchestration with automated scene management for trigger-based control; BACnet IP and OPC-UA data forwarding to external BMS or SCADA systems; and a drag-and-drop HMI/SCADA dashboard builder with real-time multi-channel alarms.
LNS-INTEGRATION
Unterstützung für UDP, LoRa Basics™ Station, LORIOT und einen internen Chirpstack LNS.
LoRaWAN-BACKHAUL
Erweitern Sie Ihr LoRaWAN-Netzwerk um redundante Dual-SIM-Mobilfunk- und WLAN-Backhaul-Verbindungen.
BUILDING PROTOCOL
KNX TP + KNXnetIP, BACnet MS/TP, Modbus RTU, M-Bus, and OPC-UA onboard.
BETRIEBSSYSTEM
RobustOS Pro – Vollständiges Linux Debian-Betriebssystem für das Hosting von IoT-Anwendungen.
RCMS AN BORD
RCMS Cloud-Geräteverwaltung für verbesserte Skalierbarkeit aktiviert.
Example LG5120 Use Cases
Commercial Buildings & Offices

Modern commercial buildings run HVAC, lighting, access control, and sub-metering on separate subsystems that rarely share data. The LG5120 consolidates them — KNX TP handles lighting and room controllers, Modbus or BACnet MS/TP connects HVAC and VFDs, LoRaWAN picks up occupancy and IAQ sensors, and the E2C Facility Suite aggregates the combined data stream locally. Automated scene logic adjusts climate and lighting based on occupancy patterns without waiting for cloud instructions, while the built-in dashboard makes consumption and comfort metrics visible to facilities teams in real time.
Energy Management & Carbon

The M-Bus port aggregates heat, water, and gas meter readings from distributed sub-metering networks. The P1/DSMR port pulls high-resolution electricity consumption data directly from smart meters in the Netherlands, Belgium, and other compatible markets. Combined with LoRaWAN-connected energy monitoring sensors and the E2C Facility Suite’s local processing, the LG5120 can generate granular consumption records and forward structured energy data to RCMS or third-party carbon reporting platforms — supporting energy audit requirements and carbon-neutrality targets without manual data collection.
Healthcare, Campus & Facilities

Hospitals and schools share a demanding operational profile: continuous environmental monitoring, strict energy compliance requirements, and facilities staff who need clear visibility without deep technical expertise. The LG5120’s local processing ensures that alarm conditions — temperature deviation in a pharmacy cold store, CO₂ levels in a classroom — trigger responses at the edge with minimal latency. BACnet IP and OPC-UA data forwarding integrates with existing BMS and SCADA platforms already deployed in larger facilities, without requiring a full system replacement.
Suchen Sie nach weiteren Anwendungsfällen?
Mit Millionen von Robustel-Geräten, die in mehr als 100 Ländern im Einsatz sind, ist es unmöglich, alle oben genannten Anwendungsfälle zu erfassen. Entdecken Sie über die folgenden Links einige der spannenden und innovativen Möglichkeiten, wie unsere Technologie weltweit Wirkung zeigt.
Dieses Gerät ist RCMS-fähig.
RCMS ist eine cloudbasierte IoT-Geräteverwaltungsplattform, die Ihnen Echtzeit-Transparenz über Ihre gesamte Robustel-Flotte bietet. So können Sie jederzeit und von überall aus Fehler beheben, Updates durchführen und die Leistung optimieren, ohne Techniker vor Ort entsenden zu müssen.
Produktbefestigungsoptionen
Tischhalterung

DIN-Schienenmontage

Wandhalterung

HINWEIS: Das Produkt befindet sich noch in der Entwicklung. Die Spezifikationen können sich bis zur Produktion noch ändern.
Systemarchitektur
|
Betriebssystem |
RobustOS Pro |
|
CPU |
Quad-core Cortex-A53, 1.6 GHz |
|
NPU |
2.3 TOPS |
|
RAM |
8 GB DDR4 |
|
Blitz |
64 GB eMMC |
Mobilfunk
|
Unterstützte Technologien |
4G/LTE, 3G, 2G |
|
Antennen |
2 (HAUPT + DIV) |
|
Steckverbinder |
SMA-K |
|
SIM |
2 x Mini-SIM (2FF) |
Ethernet
|
Ethernet-Anschlüsse |
2 x RJ45, 10/100/1000 Mbps, compliant with 1000BASE-T; configurable as 1 x WAN + 1 x LAN or 2 x LAN |
|
Magnetisolationsschutz |
1.5 kV |
LoRa
|
Antennen |
1 |
|
Steckverbinder |
RP-SMA-K |
|
Frequenzen |
US915 |
|
Kanalkapazität |
Supports up to 8 channels receiving data simultaneously |
Serielle Schnittstelle
|
Serielle Schnittstellen |
1 x M-Bus, 1 x KNX, 1 x P1, 2 x isolated RS-485, 1 x RS-232 |
|
Steckverbinder |
3,5-mm-Anschlussblock |
|
Signaldefinition |
M-bus: M+, M- |
Digitaler Ein-/Ausgang
|
DI/DO-Ports |
2 x DI + 2 x DO, wet contact |
|
Steckverbinder |
3,5-mm-Anschlussblock |
|
Isolation |
Bidirectional optocoupler for DI; unidirectional optocoupler for DO |
|
Absolute Maximum Voltage |
+30 VDC |
|
Absolute Maximum Current |
100 mA |
|
Signaldefinition |
DI1+, DI2+, DIcom, DO1+, DO2+, DOcom |
Analog Input Port
|
Number of interfaces |
2 x AI |
|
Data reading type |
Voltage / Current type, software configurable |
|
Voltage input range |
0–24 V |
|
Current input range |
4–20 mA |
|
Signal definition |
AI1+, GND, AI2+, GND |
Wi-Fi Interface
|
Number of antennas |
1 x RP-SMA-K, supporting only 1T1R |
|
Normen |
802.11 a/b/g/n/ac/ax, supports AP and client modes |
|
Frequency bands |
2.412–2.472 GHz (2.4 GHz ISM band) |
Andere Schnittstellen
|
GNSS |
Integrated GNSS with Cellular module |
|
SD |
1 x microSD |
|
Reset-Taste |
1 x RST |
|
LED-Anzeigen |
1 x RUN, 1 x Signal, 1 x USR, and 1 x MDM |
|
Aufsichtsbehörde |
Extern |
|
USB |
1 x USB 3.0 (host), Type A, 5 V, 500 mA |
|
RTC |
Remains functional up to 7 days after power loss |
Stromversorgung und Verbrauch
|
PSU-Anschluss |
2-poliger 3,5-mm-Anschlussblock mit Verriegelung |
|
Eingangsspannung |
12/24/48 V DC, 9–60 V DC, |
|
Stromverbrauch |
Leerlauf: 5 W bei 12 V |
|
Empfohlene Stromversorgung |
12 V DC/1,5 A Netzteil |
Physikalische Eigenschaften
|
Eindringungsschutz |
IP30 |
|
Gehäuse & Gewicht |
Metal, 560 g |
|
Abmessungen |
49 x 105 x 128 mm |
|
Installationsoptionen |
Tischgerät, Wandhalterung und 35-mm-DIN-Schiene |
|
Betriebstemperatur |
-40 bis +70 °C |
|
Lagertemperatur |
-40 bis +85 °C |
|
Relative Luftfeuchtigkeit |
5 – 95 % relative Luftfeuchtigkeit (nicht kondensierend) |
Software-Funktionen
|
LoRaWAN-Protokolle |
V1.0.4 Klasse A/Klasse B/Klasse C |
|
Netzwerkprotokolle |
PPP, PPPoE, ARP, VLAN, ICMP, NAT, TCP, UDP, DHCP, DNS, DDNS, NTP, HTTP, HTTPS, Telnet, SSH2, SMTP, Static Routing, etc. |
|
VPN-Tunnel |
IPsec, OpenVPN, GRE, L2TP, PPTP, DMVPN, WireGuard |
|
Firewalls |
DMZ, Anti-DDoS, Filterung (IP/Domänenname/MAC-Adresse), Port-Mapping, Zugriffskontrolle |
|
Fernverwaltung |
RCMS, Web, CLI, SMS |
|
Serielle Schnittstellenprotokolle |
Transparent, TCP-Client/Server, UDP, Modbus RTU-Gateway |
|
SIM-Verwaltung |
Smart Roaming V3, Language, etc. |
|
Optionale Apps |
Request on demand |
E2C Facility Suite
|
LNS configuration |
Built-in LoRaWAN Network Server with zero-code sensor integration |
|
Data collection |
Unified polling for KNX, BACnet, Modbus, and OPC-UA protocols |
|
Logic Orchestration & Scenario Management |
Node-RED orchestration and automated scene management for trigger-based control |
|
Data forwarding |
Converts edge data into BACnet/IP and OPC UA data streams for external systems |
|
Alarms and Visualization |
Real-time multi-channel alerts and a drag-and-drop HMI/SCADA dashboard builder |
Softwareentwicklungs-Kit (SDK)
|
Unterstützte Programmiersprachen |
C, C++, Python, Java, Node.js usw. (für Benutzer zur Entwicklung eigener Anwendungen) |
|
Flash für SDK verfügbar |
60 GB |
|
Für SDK verfügbarer RAM |
7 GB |
Regulatorische und Typgenehmigungen
|
Umwelt |
RoHS 2.0 |
|
EMI |
EN 55032 Leitungsgebundene Störaussendung Klasse B |
|
EMS |
EN 61000-4-2 (ESD) Contact Level 3 |
Verfügbare Modelle
|
Modell |
Unterstützte Frequenzbänder |
Unterstützte LoRa-Frequenz |
Zertifizierungen |
Bestellcode |
Inhalt der Verpackung |
|
LG5120-GBKGC-4L-A35GL |
4G: |
EU868 |
– |
A016000001 |
1 x LG5120 |
|
LG5120-GCKGC-4L-A35GL |
4G: |
AU915 |
– |
A016000002 |
1 x LG5120 |
|
LG5120-GEKGC-4L-A35GL |
4G: |
AS923 |
– |
A016000003 |
1 x LG5120 |
HINWEIS:
1. Für weitere Informationen zu regionalen und netzspezifischen Varianten kontaktieren Sie uns bitte unter
2. * Kennzeichnet eine laufende Zertifizierung
LG5120 Downloads
Bitte beachten Sie, dass alle Produkt-Downloads nun in der Robustel-Wissensdatenbank (https://support.robustel.com) zu finden sind. Über die Schaltflächen unten gelangen Sie zu den entsprechenden Abschnitten für jedes Produkt.
Produktdokumentation
Firmware, Software und Anwendungen
Mehr von Robustel finden








