Robustel LG5120

Intelligent Building Control Center for KNX, BACnet, M-Bus, LoRaWAN and Edge Automation


The Robustel LG5120 is an industrial-grade edge computing gateway engineered specifically for building automation and facility management. Where most IoT gateways aggregate data and forward it upstream, the LG5120 is designed to act on it locally — running automation logic, triggering controls, and generating dashboards at the edge while syncing with cloud platforms for centralised reporting and fleet management.

The hardware is built around the protocols buildings actually use. A dedicated KNX TP port and KNXnetIP over Ethernet connect directly to lighting systems, HVAC controllers, and room management units without a protocol converter. Two isolated RS-485 ports handle Modbus RTU and BACnet MS/TP field devices. M-Bus manages heat, water, and energy meter networks. A dedicated P1/DSMR port (up to 115,200 bps) connects directly to high-speed Dutch smart meters for real-time consumption data — particularly relevant for EU868 deployments in the Netherlands and Belgium. Two software-configurable analog inputs (0–24V or 4–20mA) accommodate sensors that don’t use a digital bus. An onboard Semtech SX1302 LoRaWAN chipset covers wireless sensors — temperature, humidity, occupancy, CO₂ — across 8 simultaneous channels on EU868, AU915, or AS923 frequency plans.

Processing runs on a Quad-core ARM Cortex-A53 at 1.6 GHz with an integrated NPU rated at 2.3 TOPS, 8 GB DDR4, and 64 GB eMMC — with 7 GB of RAM and 60 GB of flash available to the SDK. The E2C Facility Suite provides the software framework: unified data acquisition across KNX, BACnet, Modbus, and OPC-UA; Node-RED orchestration with automated scene management for trigger-based control; BACnet IP and OPC-UA data forwarding to external BMS or SCADA systems; and a drag-and-drop HMI/SCADA dashboard builder with real-time multi-channel alarms.

INTÉGRATION LNS

Prise en charge de UDP, LoRa Basics™ Station, LORIOT et d'un Chirpstack LNS interne.

Réseau de raccordement LoRaWAN

Ajoutez une connexion cellulaire redondante double SIM et une connexion Wi-Fi à votre réseau LoRaWAN.

BUILDING PROTOCOL

KNX TP + KNXnetIP, BACnet MS/TP, Modbus RTU, M-Bus, and OPC-UA onboard.

SYSTÈME D'EXPLOITATION

RobustOS Pro – Système d'exploitation Linux Debian complet pour l'hébergement d'applications IoT.

RCMS À BORD

Gestion des appareils RCMS Cloud activée pour une évolutivité améliorée.

Example LG5120 Use Cases

Commercial Buildings & Offices

Modern commercial buildings run HVAC, lighting, access control, and sub-metering on separate subsystems that rarely share data. The LG5120 consolidates them — KNX TP handles lighting and room controllers, Modbus or BACnet MS/TP connects HVAC and VFDs, LoRaWAN picks up occupancy and IAQ sensors, and the E2C Facility Suite aggregates the combined data stream locally. Automated scene logic adjusts climate and lighting based on occupancy patterns without waiting for cloud instructions, while the built-in dashboard makes consumption and comfort metrics visible to facilities teams in real time.

Energy Management & Carbon

The M-Bus port aggregates heat, water, and gas meter readings from distributed sub-metering networks. The P1/DSMR port pulls high-resolution electricity consumption data directly from smart meters in the Netherlands, Belgium, and other compatible markets. Combined with LoRaWAN-connected energy monitoring sensors and the E2C Facility Suite’s local processing, the LG5120 can generate granular consumption records and forward structured energy data to RCMS or third-party carbon reporting platforms — supporting energy audit requirements and carbon-neutrality targets without manual data collection.

Healthcare, Campus & Facilities

Hospitals and schools share a demanding operational profile: continuous environmental monitoring, strict energy compliance requirements, and facilities staff who need clear visibility without deep technical expertise. The LG5120’s local processing ensures that alarm conditions — temperature deviation in a pharmacy cold store, CO₂ levels in a classroom — trigger responses at the edge with minimal latency. BACnet IP and OPC-UA data forwarding integrates with existing BMS and SCADA platforms already deployed in larger facilities, without requiring a full system replacement.

Vous recherchez d'autres cas d'utilisation ?


Avec des millions d'appareils Robustel déployés dans plus de 100 pays, il est impossible de répertorier tous les cas d'utilisation ci-dessus. Explorez les liens ci-dessous pour découvrir certaines des façons passionnantes et innovantes dont notre technologie a un impact dans le monde entier.

Cet appareil est compatible RCMS.


RCMS est une plateforme de gestion des appareils IoT basée sur le cloud qui vous offre une visibilité en temps réel sur l'ensemble de votre parc Robustel. Vous pouvez ainsi dépanner, mettre à jour et optimiser les performances à tout moment et en tout lieu, sans avoir à envoyer d'ingénieurs sur site.

Options de montage du produit

Support de bureau

Montage sur rail DIN

Support mural

REMARQUE : Le produit est encore en cours de développement, les spécifications sont susceptibles d'être modifiées jusqu'à la mise en production.

Architecture du système

Système d'exploitation

RobustOS Pro

processeur

Quad-core Cortex-A53, 1.6 GHz

NPU

2.3 TOPS

RAM

8 GB DDR4

Flash

64 Go eMMC

Cellulaire

Technologies prises en charge

4G/LTE, 3G, 2G

Antennes

2 (PRINCIPAL + DIV)

Connecteur

SMA-K

SIM

2 x Mini SIM (2FF)

Ethernet

Ports Ethernet

2 x RJ45, 10/100/1000 Mbps, compliant with 1000BASE-T; configurable as 1 x WAN + 1 x LAN or 2 x LAN

Protection par isolation magnétique

1.5 kV

LoRa

Antennes

1

Connecteur

RP-SMA-K

Fréquences

US915
EU868
AU915
AS923

Capacité du canal

Supports up to 8 channels receiving data simultaneously

Port série

Ports série

1 x M-Bus, 1 x KNX, 1 x P1, 2 x isolated RS-485, 1 x RS-232

Connecteur

Bornier 3,5 mm

Définition du signal

M-bus: M+, M-
KNX: K+, K-
P1: P1-R, P1-D, GND
RS-232: TXD, RXD, GND
RS-485: Data+(A), Data-(B), GND

Entrée/sortie numérique

Ports DI/DO

2 x DI + 2 x DO, wet contact

Connecteur

Bornier 3,5 mm

Isolement

Bidirectional optocoupler for DI; unidirectional optocoupler for DO

Absolute Maximum Voltage

+30 VDC

Absolute Maximum Current

100 mA

Définition du signal

DI1+, DI2+, DIcom, DO1+, DO2+, DOcom

Analog Input Port

Number of interfaces

2 x AI

Data reading type

Voltage / Current type, software configurable

Voltage input range

0–24 V

Current input range

4–20 mA

Signal definition

AI1+, GND, AI2+, GND

Wi-Fi Interface

Number of antennas

1 x RP-SMA-K, supporting only 1T1R

Normes

802.11 a/b/g/n/ac/ax, supports AP and client modes

Frequency bands

2.412–2.472 GHz (2.4 GHz ISM band)
5.15–5.825 GHz (5 GHz ISM band)

Autres interfaces

GNSS

Integrated GNSS with Cellular module

SD

1 x microSD

Bouton de réinitialisation

1 x RST

Indicateurs LED

1 x RUN, 1 x Signal, 1 x USR, and 1 x MDM

organisme de surveillance

Externe

USB

1 x USB 3.0 (host), Type A, 5 V, 500 mA

RTC

Remains functional up to 7 days after power loss

Alimentation électrique et consommation

Connecteur PSU

Bornier à 2 broches de 3,5 mm avec verrouillage

Tension d'entrée

12/24/48 V DC, 9–60 V DC,
reverse polarity protection,
surge protection

Consommation électrique

Veille : 5 W à 12 V
Max : 20 W à 12 V

Alimentation électrique recommandée

Adaptateur secteur 12 V CC/1,5 A

Caractéristiques physiques

Protection contre les infiltrations

IP30

Boîtier et poids

Metal, 560 g

Dimensions

49 x 105 x 128 mm

Options d'installation

Bureau, fixation murale et rail DIN 35 mm

Température de fonctionnement

-40 à +70 °C

Température de stockage

-40 à +85 °C

Humidité relative

5 à 95 % HR (sans condensation)

Fonctionnalités du logiciel

Protocoles LoRaWAN

V1.0.4 Classe A/Classe B/Classe C

Protocoles réseau

PPP, PPPoE, ARP, VLAN, ICMP, NAT, TCP, UDP, DHCP, DNS, DDNS, NTP, HTTP, HTTPS, Telnet, SSH2, SMTP, Static Routing, etc.

Tunnels VPN

IPsec, OpenVPN, GRE, L2TP, PPTP, DMVPN, WireGuard

Pare-feu

DMZ, anti-DDoS, filtrage (adresse IP/nom de domaine/adresse MAC), mappage de ports, contrôle d'accès

Gestion à distance

RCMS, Web, CLI, SMS

Protocoles de port série

Transparent, client/serveur TCP, UDP, passerelle Modbus RTU

Gestion des cartes SIM

Smart Roaming V3, Language, etc.

Applications facultatives

Request on demand

E2C Facility Suite

LNS configuration

Built-in LoRaWAN Network Server with zero-code sensor integration

Data collection

Unified polling for KNX, BACnet, Modbus, and OPC-UA protocols

Logic Orchestration & Scenario Management

Node-RED orchestration and automated scene management for trigger-based control

Data forwarding

Converts edge data into BACnet/IP and OPC UA data streams for external systems

Alarms and Visualization

Real-time multi-channel alerts and a drag-and-drop HMI/SCADA dashboard builder

Kit de développement logiciel (SDK)

Langages de programmation pris en charge

C, C++, Python, Java, Node.js, etc. (pour permettre aux utilisateurs de développer leurs propres applications)

Flash disponible pour SDK

60 GB

Mémoire RAM disponible pour le SDK

7 GB

Homologations réglementaires et homologations de type

Environnemental

RoHS 2.0

EMI

EN 55032 Émissions conduites Classe B
EN 55032 Émissions rayonnées Classe B

EMS

EN 61000-4-2 (ESD) Contact Level 3
EN 61000-4-3 (RS) Level 3
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge)  Level 3, AC Mains Power Port; Level 3, Signal Ports
EN 61000-4-6 (CS) Level 3
EN 61000-4-11 (Dips)

Modèles disponibles

Modèle

Bandes de fréquences prises en charge

Fréquence LoRa prise en charge

Certifications

Code de commande

Contenu du paquet

LG5120-GBKGC-4L-A35GL
EU

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28
LTE TDD: B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

EU868

A016000001

1 x LG5120
(B Code: B016000001)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GCKGC-4L-A35GL
ANZ

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28
LTE TDD: B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AU915

A016000002

1 x LG5120
(B Code: B016000002)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

LG5120-GEKGC-4L-A35GL
Asia

4G:
LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28
LTE TDD: B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AS923

A016000003

1 x LG5120
(B Code: B016000003)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x DIN Rail Mounting Kit

REMARQUE :
1. Pour plus d'informations sur les variantes régionales et spécifiques aux opérateurs, veuillez nous contacter à l'adresse
2. * Indique une certification en cours

LG5120 Downloads

Veuillez noter que tous les téléchargements de produits se trouvent désormais dans la base de connaissances Robustel (https://support.robustel.com). Les boutons ci-dessous vous dirigeront vers les sections correspondantes pour chaque produit.

Documentation produit


Micrologiciels, logiciels et applications

En savoir plus sur Robustel