Robustel LG3120e

Industrial Edge Computing LoRaWAN Gateway with 4G, eSIM, Wi-Fi, Serial and I/O


The Robustel LG3120e is a high-performance industrial LoRaWAN gateway built for sites where connectivity and local intelligence need to arrive together. Running on RobustOS Pro (Debian 11 Bullseye) on a Quad-core ARM Cortex-A53 at 2.0 GHz with 2 GB DDR4 RAM and 6 GB of SDK-available flash, it processes, filters, and acts on field data locally — reducing cloud dependency and the latency that comes with it.

A native LoRaWAN Network Server handles LoRaWAN V1.0.4 Class A and Class C device management on-device across EU868, AU915, US915, and AS923 frequency plans. Pre-installed device profiles and codecs for major LoRa sensor families enable zero-configuration onboarding — attach a supported sensor and it begins reporting without manual decoder setup.

MFF2 eSIM alongside a physical Mini SIM (2FF) slot, dual cellular antennas, and dual-band Wi-Fi 6 (802.11 a/b/g/n/ac/ax, 2.4 GHz and 5 GHz) provide flexible backhaul. TPM 2.0 provides hardware-level key storage and attestation. An onboard RTC retains timekeeping for up to five days after power loss — relevant for remote sites where power interruptions are a known operational condition.

Fleet operations are managed through RCMS: real-time device status, geospatial dashboard, OTA firmware and configuration delivery, and RobustVPN for secure remote access without a site visit.

LNS INTEGRATION

Support for UDP, LoRa Basics™ Station, LORIOT and an Internal Chirpstack LNS.

LoRaWAN BACKHAUL

Add Dual-SIM redundant cellular and Wi-Fi back-haul to your LoRaWAN Network.

E2C FIELD SUITE

Unified data integration across LoRaWAN, Modbus, OPC-UA, and BACnet.

OPERATING SYSTEM

RobustOS Pro – Full Linux Debian Operating System for hosting IoT applications.

RCMS ON-BOARD

RCMS Cloud device management enabled for enhanced scalability.

Example LG3120e Use Cases

Smart Farming/Agriculture

Soil sensors, weather stations, irrigation controllers, and water-quality nodes across large agricultural or environmental monitoring sites share a common challenge: distances too great for wired runs, and cloud connectivity that cannot be assumed reliable. The LG3120e’s integrated LNS manages end-node registration and uplink collection on-device. The Quad-core A53 processor and 2 GB RAM support local pre-processing and buffering that keeps data intact through connectivity gaps, while cellular and dual-band Wi-Fi backhaul provide flexibility based on what infrastructure exists at the site.

Remote Asset Monitoring

Distributed field assets — wellheads, pressure regulators, pump stations, tank farms — are often too spread out for wired networks and too critical for unreliable connectivity. The LG3120e addresses both constraints: built-in LoRaWAN covers scattered sensor nodes across a site without cabling, while the integrated LNS and E2C Field Suite aggregate LoRa sensor data alongside Modbus or OPC-UA readings from legacy field instruments into a single outbound stream. Local Node-RED logic can trigger DO outputs or SMS alerts on threshold breaches, independently of cloud availability.

Industrial Facilities & Plant

In manufacturing and process environments, LoRa sensors for IAQ, temperature, vibration, and energy sub-metering operate alongside wired PLCs and HMI systems running Modbus or BACnet. The LG3120e bridges both worlds via its dual RS-232/485 ports and E2C Field Suite, unifying wired instrument data and wireless sensor traffic at the edge before forwarding to SCADA or cloud analytics. Pre-installed sensor profiles reduce integration time for common LoRa devices; the built-in dashboard surfaces key metrics locally without waiting for cloud round-trips.

Looking for more use cases?


With millions of Robustel devices deployed across more than 100 countries, it’s impossible to capture every use case above. Explore the links below to discover some of the exciting and innovative ways our technology is making an impact worldwide.

This Device is RCMS Ready


RCMS is a cloud-based IoT device management platform that gives you real-time visibility across your entire Robustel fleet. So you can troubleshoot, update, and optimize performance from anywhere at anytime, without sending engineers to site.

Product Mounting Options

Desktop Mount

DIN Rail Mount

Wall Mount

System Architecture

Operating System

RobustOS Pro

CPU

Quad-core ARM Cortex-A53@2.0 GHz

RAM

2 GB LPDDR4

Flash

8 GB eMMC

Cellular

Supported Technologies

4G/LTE, 3G, 2G

Antennas

2 (MAIN + DIV)

Connector

SMA-K

SIM

1 x Mini SIM (2FF)

eSIM

1 x eSIM (MFF2); GSMA SGP.22 compliant; supports profile download/removal and typically up to 8 eSIM profiles

Ethernet

Ethernet Ports

2 x 10/100 Mbps, LAN or WAN

Magnet Isolation Protection

1.5 kV

LoRa

Antennas

1

Connector

SMA-K

Frequencies

US915
EU868
AU915
AS923

Channel capacity

Supports up to 8 channels receiving data simultaneously

Serial Port

Serial Ports

2 x RS-232/485 (software configurable)

Connector

6-pin 3.5 mm terminal block with lock

Baud Rate

300–115200 bps

Signal Definition

RS-232: TXD, RXD, GND
RS-485: Data+ (A), Data- (B), GND

Digital Input/Output

DI/DO Ports

2 x DI + 2 x DO, wet contact

Connector

8-pin 3.5 mm terminal block with lock (DI/DO)

Absolute Maximum Voltage

+30 VDC

Absolute Maximum Current

100 mA

Signal Definition

DI1+, DI1-, DI2+, DI2-, DO1+, DO1-, DO2+, DO2-

Wi-Fi Interface

Number of antennas

1, supporting only 1T1R

Connector

RP-SMA-K

Standards

802.11 a/b/g/n/ac/ax; supports AP and client modes

Frequency bands

2.412–2.472 GHz (2.4 GHz ISM band)
5.15–5.825 GHz (5 GHz ISM band)

Other Interfaces

TPM

TPM 2.0

Reset Button

1 x RST

LED Indicators

1 x RUN, 1 x RSSI, 1 x MDM, and 1 x USR

microSD

1 x microSD, supporting up to 2 TB

Watchdog

External

USB

1 x USB 2.0 (host), Type A, 5 V, 500 mA
1 x USB 2.0, Type C, console port

RTC

Remains functional up to 5 days after power loss

Power Supply & Consumption

PSU Connector

2-pin 3.5 mm terminal block with lock

Input Voltage

12/24 VDC, 9–36 VDC
Reverse polarity protection, surge protection

Power Consumption

Idle: 1.5 W@12 V
Max: 15 W@12 V

Recommended Power Supply

12 V DC/1.5 A power adapter

Physical Characteristics

Ingress Protection

IP30

Housing & Weight

Metal, 587 g

Dimensions

49 x 105 x 128 mm

Installation Options

Desktop, Wall Mount and 35mm DIN Rail

Operating Temperature

-25 – +70°C

Storage Temperature

-40 – +85°C

Relative Humidity

5 – 95% RH (non-condensing)

Software Features

LoRaWAN Protocols

V1.0.4 Class A/Class B/Class C

Network Protocols

PPP, PPPoE, ARP, VLAN, ICMP, NAT, TCP, UDP, DHCP, DNS, DDNS, NTP, HTTP, HTTPS, Telnet, SSH2, SMTP, Static Routing, etc.

VPN Tunnels

IPsec, OpenVPN, GRE, L2TP, PPTP, DMVPN, WireGuard

Firewalls

DMZ, anti-DDoS, Filtering (IP/Domain name/MAC address), Port Mapping, Access Control

Remote Management

RCMS, Web, CLI, SMS

Serial Port Protocols

Transparent, TCP Client/Server, UDP, Modbus RTU Gateway

SIM Management

Smart Roaming V3, Language, eSIM Management, E2C Field Suite

Optional Apps

Request on demand

Software Development Kit (SDK)

Supported Programming Languages

C, C++, Python, Java, Node.js, etc. (for users to develop own applications)

Flash available for SDK

6 GB

RAM available for SDK

1.5 GB

Regulatory and Type Approvals

Environmental

RoHS 2.0

EMI

EN 55032 Conducted Emission Class B
EN 55032 Radiated Emission Class B

EMS

EN 61000-4-2 (ESD) Level 3
EN 61000-4-3 (RS) Level 3
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge) Level 3, AC Mains Power Port; Level 3, Signal Ports
EN 61000-4-6 (CS) Level 3

Available Models

Model

Supported Frequency Bands

Supported LoRa Frequency

Certifications

Order Code

Package Contents

LG3120e-ABJAA-4L-A35GL
EU

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

EU868

CE*, UKCA*

A015800001

1 x Gateway (B Code: B015800001)
1 x Wall Mounting Kit

LG3120e-ABJAA-4L-A35GL
EU

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

EU868

CE*, UKCA*

A015800002

1 x Gateway (B Code: B015800001)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x Wall Mounting Kit

LG3120e-ACJAA-4L-A35GL
AU

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AU915

RCM*

A015800003

1 x Gateway (B Code: B015800002)
1 x Wall Mounting Kit

LG3120e-ACJAA-4L-A35GL
AU

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AU915

RCM*

A015800004

1 x Gateway (B Code: B015800002)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x Wall Mounting Kit

LG3120e-ADJAA-4L-A35GL
NA

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

US915

FCC*, IC*

A015800005

1 x Gateway (B Code: B015800003)
1 x Wall Mounting Kit

LG3120e-ADJAA-4L-A35GL
NA

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

US915

FCC*, IC*

A015800006

1 x Gateway (B Code: B015800003)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x Wall Mounting Kit

LG3120e-AEJAA-4L-A35GL
Asia

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AS923

CE*

A015800007

1 x Gateway (B Code: B015800004)
1 x Wall Mounting Kit

LG3120e-AEJAA-4L-A35GL
Asia

4G: LTE FDD: B1/2/3/4/5/7/8/12/13/18/19/20/25/26/28/66
LTE TDD: B34/B38/39/40/41
3G: WCDMA: B1/2/4/5/6/8/19
2G: GSM: B2/3/5/8

AS923

CE*

A015800008

1 x Gateway (B Code: B015800004)
2 x Cellular Antenna
1 x Wi-Fi Antenna
1 x LoRa Antenna
1 x Power Adapter
1 x Wall Mounting Kit

NOTE:
1. For more information about regional & carrier specific variants please contact us
2. * Denotes Certification in Progress

LG3120e Downloads

Please note that all product downloads are now located on the Robustel Knowledge Base (https://support.robustel.com) the buttons below will take you to the relevant sections for each product.

Product Documentation


Firmware, Software & Applications

Find More From Robustel